Why gas is hard on an old flue
Wood smoke leaves a chimney hot and fairly dry. Gas exhaust behaves differently. Burning natural gas makes a lot of water vapor, and the exhaust from a modern gas unit runs cooler than wood smoke, so that vapor can condense on the inside of the flue before it reaches the top. The water that forms is mildly acidic. Over seasons it eats at the mortar between clay tiles and at the face of the tile itself. In an older Westminster chimney built for wood, that is the main reason a liner enters the conversation when an owner goes gas.
Whether you need one, and which kind, depends on the gas route you choose.
With a log set: the old flue may be enough
A vented log set burns in an open firebox, with plenty of room air going up the chimney along with the exhaust. That extra air keeps the flue warmer and drier than a sealed unit would. Many sound clay flues carry a log set without new lining. Sound is the key word: if the camera shows cracked tiles, open joints or missing mortar, the exhaust from a log set will find those gaps as easily as wood smoke did. Then the flue needs repair or a liner before the set goes in.
With an insert: the liner comes with the unit
An insert is built to vent through its own pipe system, and its manual names the size and type of liner it needs, run the full height of the chimney to a matching cap. Two setups are common:
- two flexible aluminum or stainless liners side by side, one for exhaust and one for fresh air
- one pipe inside another, exhaust in the center and air in the space around it
In both, the old clay flue becomes a sleeve the liners pass through. Its cracks matter less, but its top still needs a sound crown and a cap that suits the liner termination.
With a direct-vent unit: a new vent, no old flue
A direct-vent fireplace in a wall or a new chase has its own vent pipe, listed with the unit, that leaves through the wall or the roof. The old chimney, if there is one, plays no part. Some owners keep it for looks; others have it taken down below the roofline and the roof patched.
What sets a liner price
Liner work has no published figure with us. The chimney sets the job, and no two are alike. What moves it:
- the height of the chimney, which sets the length of each liner
- the liner the appliance's manual calls for
- how tight the old flue is, and whether any tile has to come out for the liners to pass
- how easy the roof is to stand and work on
- the cap and the top plate that close the flue around the liners
A Level 2 camera inspection at $410 gives us the measurements and the tile condition, and with those you get the liner as its own priced line. If you are planning an insert, ask for the liner and the unit on one quote; our installed range for an insert set into an existing firebox is $2,950 to $5,900. Ask for a liner price and tell us which gas unit you have in mind and whether the chimney has had a camera inspection in the last few years.
Cracked tile with a wood fire still in use
Not every relining call is about gas. Some Westminster owners plan to keep burning wood for a few more seasons and switch later. A cracked clay flue in a wood-burning chimney lets heat and smoke reach the brick and whatever sits next to it, and it is not something to keep burning through. There a liner rated for wood is the fix, and it can be chosen so a later move to gas does not mean paying twice. Tell us both plans and we look for a liner that serves both where the products allow it.
Signs an old flue is already struggling with gas
Some Westminster chimneys have carried a log set for years without anyone looking up the flue. Signs that the exhaust has started doing damage include a white or tan crust on the tiles near the top, flakes of tile or mortar landing on the ceramic logs, damp patches on the chimney breast inside the house, and a sour smell when the set has been off for a while. None of those prove a liner is needed, but each one is a reason to put the camera up before the next winter.
After the liner goes in
Once the liner is in and connected, the top of the chimney is closed around it and capped, so water and nesting birds cannot get into the gap between the liner and the old tile. We light the appliance, watch the draft at start-up and check the cap from the roof. You get photos of the top and, where the liner followed a camera inspection, a note of what the old flue looked like before.
Where to go from here
More on the job sits on chimney liner installation and fireplace inserts. The damper question that comes with any liner is covered in dampers after going gas. For a chimney in Westminster or a city nearby, send the details through the contact page.
Get Rafferty's Read on Your Chimney
We size the firebox, check the flue, damper and cap, and write out the gas options your house can take, each with its prep work and price. We work from Westminster across Garden Grove, Seal Beach, Bellflower and nearby cities.