Rafferty Chimney Solutions

Pellet Stove Repair, With Gas Laid Alongside

Wood Now, Gas Later?

Inside a Rafferty visit

A pellet stove is a small machine: a hopper, a feed screw, an igniter, a pair of blowers and a control board. When one part fails the stove stops or smokes. We test each in turn, fix or swap the part that failed, clean the exhaust path and the ash traps, and run a full burn cycle before we leave. If the stove is beyond saving, we price a gas insert to compare.

Feed screw jams cleared and the motor tested
Igniter checked and swapped when it fails
Both blowers cleaned and run up to speed
Ash traps and exhaust pipe brushed out
Full burn cycle run before we go

How a Pellet Stove Goes Wrong

A pellet stove sits closer to a household appliance than to a fireplace, and its faults look like appliance faults. Pellets drop from a storage bin onto a screw that turns at a pace set by the controls. The screw feeds a small cup where an electric igniter starts the fire. One fan blows air through the fire, another pushes warm air into the room, and a set of switches watches temperatures and pressure, shutting everything down if something looks wrong. When owners in Westminster call us, the complaint is usually one of a handful: the stove will not start, it starts and stops after a few minutes, the flame is lazy and dark, the room fan screeches, or the glass blackens within an hour. Each points to a short list of parts, and the usual culprit is ash. Fine ash builds in places the owner cannot reach and chokes the airflow the sensors depend on.

Repair starts with a full clean, because many faults vanish once the ash is gone and others become easier to read. We empty and brush out the burn cup, open the heat exchanger passages, vacuum the fan housings and clear the vent pipe from stove to outlet. Then we test the parts the controls depend on: the igniter for resistance, the feed motor for speed, the fans for draw, the pressure switch and its hose for blockage, and the heat sensors for the right readings. Door and glass gaskets are checked for leaks, since a stove that pulls air through a gap burns poorly and can trip its own safety. If the control board is at fault, we confirm that before replacing it, since boards are costly. Every part we change is named in the written repair figure before it is fitted.

When Gas Is the Better Spend

Pellet stoves were popular for a while as an alternative to wood, and some of the older ones now need parts that are hard to get. When we find a stove with a cracked burn chamber, a board no longer made or a pile of small faults that add up, we put two numbers side by side: what it will take to keep the pellet stove running, and what it would take to replace it with gas. If the stove sits in a masonry fireplace, the gas option is usually an insert at $2,950 to $5,900, using a new liner in the old flue. If it stands free on a hearth and vents through a wall, a sealed unit vented out through the wall is often the closer match, and that costs $4,700 to $9,450. Neither needs bags of pellets carried in, and neither needs the burn cup emptied each week.

Pellet stove repair has no published price here, because the cost depends on which part has failed and whether it is still made. When you get in touch, give us the name on the stove's badge, describe how it behaves once switched on, and note anything that flashes on its screen. If you have been weighing a move to gas anyway, mention it, and we will bring the measurements for an insert or a direct vent unit on the same trip. Pellet stoves vent through small diameter pipe that must stay clear and sealed, so every visit also covers the venting from collar to cap. Use the contact page to get started, and if the stove is running but smells of smoke indoors, shut it down and leave it off until we have looked at it.

How Rafferty Chimney Solutions Runs a Job

Chimney First

Flue and firebox checked before any gas unit is chosen

Options Compared

Logs, inserts and wall units set out one by one

Paper Estimates

Scope and price written down before work begins

First Light Shared

New gas units lit and tested with you present

More From the Rafferty List

Chimney Sweep

Tar and soot cleared from a wood flue, often the first job before a switch to gas logs or an insert.

See this job →

Chimney Inspection

A look at the flue, damper, crown and cap that tells you whether the chimney can take a gas appliance as it stands.

See this job →

Chimney Repair

Fixes to the flue, crown, joints and cap so the stack is sound enough to vent whatever burns below it.

See this job →

Fireplace Inspection

Firebox, damper, hearth, gas valve and surround checked, with notes on which gas option fits the opening.

See this job →

Fireplace Repair

Worn firebrick, a sticking damper, warped doors or a cracked hearth put right so the fireplace works again.

See this job →

Chimney Level 2 Inspection

A camera run of the whole flue plus the hidden spaces around it, called for at a sale or a change of fuel.

See this job →

Chimney Cap Installation

A steel top fitted over the flue to shed rain, keep animals out and calm downdrafts at a gas or wood fireplace.

See this job →

Chimney Flashing Repair

Leaks at the seam where roofing meets brick traced and resealed, so the ceiling beside the fireplace stays dry.

See this job →

Chimney Masonry Repair

Spalled brick and eroded joints renewed so the stack stays solid through coastal weather and the next quake.

See this job →

Chimney Rebuilds

A split or leaning stack taken down and relaid, with the option to size the new flue for a gas vent.

See this job →

Fireplace Cleaning

Old ash out, soot film and smoke marks lifted off firebox, glass doors and hearth, ready for gas logs or a fresh look.

See this job →

Gas Fireplace Cleaning

Pilot, burner ports, ceramic logs and glass tended so your converted fireplace starts first try with a calm blue base.

See this job →

Gas Fireplace Repair

Pilot, ignition, valve and remote faults on gas fireplaces found and fixed, with a leak test on every joint.

See this job →

Fireplace Remodel

A dated brick or tile face reworked, often alongside a switch to gas, with clearances set for the new unit.

See this job →

Fireplace Inserts

A sealed box fitted into an existing firebox, run on gas or wood, with a liner up to the top of the chimney.

See this job →

Wood Stove Repair

Leaky doors, cracked panels and tired baffles on wood stoves set right, or a gas stove priced in its place.

See this job →

Gas Logs

Ceramic logs on a gas burner set into the firebox you have, the quickest way to stop hauling and burning wood.

See this job →

Chimney Seismic Retrofit

Older brick chimneys braced, strapped or cut down and finished lighter so they stay put in the next big quake.

See this job →

Chimney Crown Repair

The mortar or concrete lid on the stack sealed or recast so rain stops soaking into the brick below.

See this job →

Dryer Vent Cleaning

Lint packed in the duct between the dryer and the outside wall cleared so loads dry faster and run cooler.

See this job →

Chimney Liner Installation

A stainless liner fitted inside an old flue so a gas insert, log set or stove vents through a sealed, sized pipe.

See this job →

Chimney Leak Repair

Water showing up beside the fireplace traced to its source, whether that is the top, the sides or the roof seam.

See this job →

Chimney Waterproofing

A breathable sealer applied to sound brick so rain runs off the face instead of soaking into the stack.

See this job →

Chimney Damper Repair

A rusted, stuck or warped damper freed, rebuilt or swapped for a top-sealing unit worked by a cable.

See this job →

Chimney Chase Cover

A rusted or sagging metal lid on a framed chimney replaced with a sloped stainless one made to measure.

See this job →
Ask About Going Gas